# Build a usable schematic plan

## Representation and order

Use consistent model units, world coordinates, floor elevations and stable IDs. Define a plan cut convention. Record whether room polygons are clear internal areas, centreline zones or preliminary areas; final reported usable area must correspond to the clear internal region.

1. Preserve and reference the actual input perimeter, holes and protected geometry. Build allowed proposed perimeter/structure independently.
2. Lay out programme regions and reserve circulation with real width, thresholds and service access. Test bottlenecks before small furniture.
3. Introduce realistic **declared schematic** wall/partition thickness and structure zones. Recompute room sizes after offsets. Wall material/build-up remains unresolved until specified.
4. Create actual gaps/openings connecting spaces. Add doors with clear opening, leaf/swing where applicable and approach space. Glass, open thresholds and controlled doors are different connection types. A door arc over an unbroken wall is not a door.
5. Place representative real-size activities/equipment/furniture and their use envelopes. Test the most constrained rooms first, including sanitary fitout and wheelchair manoeuvring where brief-relevant. Do not assume a labelled accessible WC is accessible.
6. Resolve windows, external doors, roof/section implications and likely structural spans at the level necessary to support the plan. Show one diagnostic section where a level change, roof, mezzanine or split level affects plausibility. Mark untested dimensions/hypotheses.
7. Recompute areas, route geometry and openings; capture actual views at a common scale.

A zone boundary need not become a wall. Use open continuity for shared public space when appropriate; enclosure follows acoustic, privacy, environmental, security and structural needs. Open space, landscape, courts and circulation can be intentionally unfilled. Account for them without forcing decorative objects onto every square metre.

## Door and circulation model

Record room/space ID, traversable connection ID, connected spaces or exterior, floor/level, public/staff/controlled role and actual opening geometry. Check that each door is on the relevant boundaries and intersects a real wall opening. A line segment near two rooms is not a verified connection.

Test both:

- **Topology:** required destinations reachable through permitted spaces and operating modes. A public WC should not be accessible only through a staff store; a necessary exit cannot depend on an assumed unlocked controlled room.
- **Geometry:** the intended body/activity/access envelope fits along a continuous path through actual openings and around wall/furniture obstructions, including turns, thresholds and level changes. Use swept/offset regions or sampled clearance analysis with declared resolution, then inspect narrow locations. Straight-line proximity and centroid-to-centroid arrows are insufficient.

Declare the required clear widths/turning criteria and their source or provisional brief status. Do not invent universal dimensions. Account for open door leaves, counter queues and furniture use where these constrain the design. An analysis overlay may cross a wall graphically, but it must not be reported as an actual traversable route.

For multi-level work, include actual stair/ramp/lift footprint, landing and vertical relationship, plus section/headroom evidence appropriate to the brief. No upper room is reachable just because two nodes are linked in a text graph. If required vertical access cannot be resolved, mark the option incomplete, or propose a lower-complexity option within permission.

## Irregular and curved geometry

Use planar region intersection/difference and point/curve containment on the actual boundary, not just bounding boxes or centroids. Holes/courts and concave notches matter. Bounding boxes may reject obvious collisions quickly but cannot establish the final result. A valid rectangle whose centroid lies inside a concave plan can still extend outside it.

Detect self-intersection, duplicates, wrong elevations, tiny slivers, overlapping rooms and ambiguous offset joins. Short wall fragments and acute corners can absorb nominal floor area without usable activity width. Test the largest required furniture/activity envelope and the residual strips. Never silently trim required area out of a room to make polygons appear clean.

## Programme and operations

Test a relevant user scenario (e.g. visitor arrival → orientation → exhibit → outdoor route → amenities/return), adapted to the student's actual programme. Test staff/service operation separately if applicable. Identify any public-service crossing rather than assuming complete separation is mandatory in a very small building.

A café, workshop, flexible classroom or exhibition room needs its relevant activity/equipment arrangement. Furnishing is evidence of capacity and usability, not decoration. For flexible use show different configurations where they are claimed; do not add their capacities or areas as simultaneous uses without a scheduling rationale.

## Drawing deliverable

Each option shows real wall thickness/openings, room IDs/names/areas, entrances, key dimensions, necessary furniture/activity/clearance tests, appropriate exterior relationship, and a scale bar generated from actual model units. Show north only if known; otherwise state it is unknown. Keep labels legible by text height, viewport layout and detail views. Never enlarge physical objects or alter geometry to make the drawing look more convincing.